Firstly,the working p rincip le and measurement p recision of the Airda - 3000Q type atmospheric wind p rofiler (AWP) were introduced. Then, a contradistinctive analysis on the wind p rofile data acquired by both AWP and synchronous balloon sounding was conducted to estimate the reliability ofAWP for detectingwind field. The results show that under the stable weather condition, the p rofiler’s detection ofwind direction and wind speed had some deviation compared by the balloon’s detection from the ground to 200 m height due to the detecting blind spots of the AWP and the ground clutter, but above 200 m, both wind field p rofiles correlated well;Under the comp lex weather condition, theirwind p rofiles had obvious deviation because the wind information on the different height acquired by AWP is a temporal average of wind field in a time period, but the wind data measured by sounding balloon on a specific height is the instantaneous value while balloon passed by.